NS060: ambient brightness monitoring
NS060 measures ambient light for automatic brightness adjustment through a connected sending, asynchronous or multifunction card with a light-sensor connector.

اكتشف شاشات LED لنشاطك التجاري ومساحة عملك.
استكشف الشاشات التجارية
استكشف وحدات التحكم وبطاقات الاستقبال ومزودات الطاقة والملحقات.
استكشف الملحقات

Compare NS060 cable-length options for brightness sensing and the separate 10G SFP Module-S for optical data links.
Choose the 5 m cable of NS060-5A when it reaches a sensor position in the same environment as the display. Confirm the control device provides the specified light-sensor connector.
Ambient-light sensing with a 5 m cableLearn more in our Shipping Policy →
Get support with product selection, compatibility, configuration, installation and after-sales service.
Contact us: service@absen.com
The NS060 variants measure ambient light for automatic LED-display brightness adjustment, with 5 m, 10 m and 30 m cable options. The 10G SFP Module-S is an optical data transceiver. Match the selected accessory to its documented host interface and installation requirements.
NS060 measures ambient light for automatic brightness adjustment through a connected sending, asynchronous or multifunction card with a light-sensor connector.
NS060-5A, NS060-10A and NS060-30A specify 5 m, 10 m and 30 m cables respectively. Position the sensor in the same environment as the LED display.
The separate SFP+ model supports duplex LC single-mode links up to 10 km. It uses an electrical edge connector and documented Ethernet or InfiniBand applications.
Mount NS060 through the substrate with its washer and nut, keep it in the display environment, and follow the documented IP65 sealing steps.
Use an NS060 variant for ambient light sensing. Use the 10G SFP Module-S for its documented single-mode optical data link; the connection types serve different functions.
Connect to a device with a light-sensor connector and place the sensor in the display environment. Follow the documented sealing and regular inspection guidance.
Verify the host supports the stated SFP+ connection and optical protocol. Use single-mode fiber and check the mechanical drawing before installation.

Find your fit
|
Model selection
Choose a model to update the comparison.
|
||||
|---|---|---|---|---|
| Product use | Monitors ambient brightness from 0 to 65,535 lux to enable automatic LED-display brightness adjustment. | Monitors ambient brightness from 0 to 65,535 lux to enable automatic LED-display brightness adjustment. | Monitors ambient brightness from 0 to 65,535 lux to enable automatic LED-display brightness adjustment. | Single-mode SFP+ optical transceiver for Ethernet and InfiniBand data links, supporting 10.3125 Gb/s. |
| Interface type | Light-sensor connection cable, 5 m for NS060-5A; connect to a device with a light-sensor connector. | Light-sensor connection cable, 10 m for NS060-10A; connect to a device with a light-sensor connector. | Light-sensor connection cable, 30 m for NS060-30A; connect to a device with a light-sensor connector. | Hot-pluggable SFP+ module with duplex LC optical receptacle and a 20-pin electrical edge connector. |
| Input voltage | 5 V DC, supplied through the connected control device. V | 5 V DC, supplied through the connected control device. V | 5 V DC, supplied through the connected control device. V | 3.14–3.46 V DC; 3.3 V supply pins identified in the pin table. V |
| Operating temperature | −20 to +70 °C; 0–99% RH, non-condensing. °C | −20 to +70 °C; 0–99% RH, non-condensing. °C | −20 to +70 °C; 0–99% RH, non-condensing. °C | 0 to +70 °C case operating temperature; 15–85% RH, non-condensing. °C |
| Specifications | ||||
| Product use | Monitors ambient brightness from 0 to 65,535 lux to enable automatic LED-display brightness adjustment. | Monitors ambient brightness from 0 to 65,535 lux to enable automatic LED-display brightness adjustment. | Monitors ambient brightness from 0 to 65,535 lux to enable automatic LED-display brightness adjustment. | Single-mode SFP+ optical transceiver for Ethernet and InfiniBand data links, supporting 10.3125 Gb/s. |
| Compatibility | Sending cards such as MSD300, MSD600 and MCTRL300, or asynchronous/multifunction cards with a light-sensor connector. The connected control device supplies power; no external sensor supply is required. | Sending cards such as MSD300, MSD600 and MCTRL300, or asynchronous/multifunction cards with a light-sensor connector. The connected control device supplies power; no external sensor supply is required. | Sending cards such as MSD300, MSD600 and MCTRL300, or asynchronous/multifunction cards with a light-sensor connector. The connected control device supplies power; no external sensor supply is required. | Documented applications: Ethernet 10GBASE-LR and InfiniBand QDR, DDR and SDR. SFF-8472 management interface and SFF-8432 form factor. Exact supported host model must be confirmed separately. |
| Input voltage | 5 V DC, supplied through the connected control device. V | 5 V DC, supplied through the connected control device. V | 5 V DC, supplied through the connected control device. V | 3.14–3.46 V DC; 3.3 V supply pins identified in the pin table. V |
| Dimensions | Sensor drawing: 83.4 ±0.1 mm axial length and 39.3 ±0.1 mm maximum body height; M30×1.5 mounting thread. Cable length is specified separately by model. mm | Sensor drawing: 83.4 ±0.1 mm axial length and 39.3 ±0.1 mm maximum body height; M30×1.5 mounting thread. Cable length is specified separately by model. mm | Sensor drawing: 83.4 ±0.1 mm axial length and 39.3 ±0.1 mm maximum body height; M30×1.5 mounting thread. Cable length is specified separately by model. mm | Drawing dimensions: 57.3 ±0.10 mm length, 13.65 ±0.10 mm body width and 8.55 ±0.10 mm height; latch region width is 13.85 ±0.10 mm. mm |
| Operating temperature | −20 to +70 °C; 0–99% RH, non-condensing. °C | −20 to +70 °C; 0–99% RH, non-condensing. °C | −20 to +70 °C; 0–99% RH, non-condensing. °C | 0 to +70 °C case operating temperature; 15–85% RH, non-condensing. °C |
| Installation | Place the sensor in the same environment as the LED display. Mount the sensor through the substrate using the illustrated washer and nut. IP65 is stated; apply outdoor waterproof adhesive at the body/substrate joint and inspect it regularly. | Place the sensor in the same environment as the LED display. Mount the sensor through the substrate using the illustrated washer and nut. IP65 is stated; apply outdoor waterproof adhesive at the body/substrate joint and inspect it regularly. | Place the sensor in the same environment as the LED display. Mount the sensor through the substrate using the illustrated washer and nut. IP65 is stated; apply outdoor waterproof adhesive at the body/substrate joint and inspect it regularly. | Hot-pluggable SFP+ form factor; use the documented mechanical envelope, connector pin-out and a compatible host. |
| Interface type | Light-sensor connection cable, 5 m for NS060-5A; connect to a device with a light-sensor connector. | Light-sensor connection cable, 10 m for NS060-10A; connect to a device with a light-sensor connector. | Light-sensor connection cable, 30 m for NS060-30A; connect to a device with a light-sensor connector. | Hot-pluggable SFP+ module with duplex LC optical receptacle and a 20-pin electrical edge connector. |
| Application | Outdoor ambient-light monitoring for an LED display using a compatible control device. | Outdoor ambient-light monitoring for an LED display using a compatible control device. | Outdoor ambient-light monitoring for an LED display using a compatible control device. | Single-mode optical data links for Ethernet 10GBASE-LR or the documented InfiniBand modes. |
| Transmission distance | Not documented | Not documented | Not documented | Up to 10,000 m under the documented fiber conditions. m (Single-mode fiber (SMF); nominal optical wavelength 1310 nm (PDF page 5).) |
| Maximum power consumption | 0.45 W (Maximum consumption of one light sensor tested at 5 V input and 25 °C ambient; not a rated or typical value.) | 0.45 W (Maximum consumption of one light sensor tested at 5 V input and 25 °C ambient; not a rated or typical value.) | 0.45 W (Maximum consumption of one light sensor tested at 5 V input and 25 °C ambient; not a rated or typical value.) | 1.2 W (Maximum operating consumption per transceiver end; varies with output swing and pre-emphasis. Not absolute-maximum chip dissipation.) |
Check the stated conditions for each model before comparing values.
الأسئلة الشائعة
The manufacturer specifies cable lengths of 5 m for NS060-5A, 10 m for NS060-10A and 30 m for NS060-30A. Choose a cable length that lets the sensor occupy the same environment as the LED display.
The NS060 documentation states that no external power supply is required. It connects to a sending, asynchronous or multifunction card with a light-sensor connector; the sensor rated voltage is 5 V DC.
No. The 10G SFP Module-S is an optical data transceiver with duplex LC and a 20-pin electrical connector. NS060 measures ambient brightness through a light-sensor connection. Select according to the required function.
NS060 measures 0 to 65,535 lux. Install it in the same environment as the LED display using the documented M30×1.5 mounting arrangement; the specification states IP65 and calls for outdoor waterproof adhesive at the body/substrate joint.
It is a single-mode SFP+ transceiver for 10GBASE-LR and the listed InfiniBand modes, with duplex LC and a documented reach up to 10,000 m under the stated fiber conditions. Confirm the exact host separately.
The current downloads are NS060 Light Sensor Specifications V1.1.5 and 10G SFP Module-S Optical Module Specifications V1.0.0, both in English.
CONTACT
Send the exact model and your project requirements to discuss the next step.
Contact sales